Time-R Digital Timer

TIME-R Digital Timer

Mojo Cow
Add to Cart

Take greater control of your grow room with the TIME-R Digital Timer. Designed for hydroponics and controlled growing environments, the TIME-R offers versatile programming options, with adjustable ON/OFF intervals as short as one second.

Whether you're automating intermittent nutrient dosing, managing irrigation cycles or controlling ventilation, the TIME-R provides flexible timing control for a wide range of growing applications.


Key Features

Grow-Room Friendly Display
A large, easy-to-read screen with a soft green backlight for convenient viewing.

Precision Interval Timing
Set equipment to switch ON and OFF for intervals as short as one second. Ideal for applications requiring short, repeatable operating cycles, including nutrient dosing and aeroponic systems.

Intuitive Controls:
The cross-button layout makes it easier to navigate the settings and program your timer.

Versatile Equipment Control:
Suitable for a range of applications involving compatible fans, pumps, and irrigation equipment, within the timer's rated electrical specifications..

Time-R Hydroponics Timer


Advanced Operating Modes
Timed Mode – Scheduled ON/OFF periods
Program up to 15 ON/OFF settings per day. Ideal for scheduled equipment operation, such as lighting, ventilation and reservoir mixing.

Repeat Mode – ON/OFF interval cycles
Automate equipment switch ON and OFF at regular intervals, from 1 second to 99 hours. Useful for intermittent nutrient dosing, water circulation and air circulation.

Combined Mode – Repeating ON/OFF cycles
Combine scheduled operating windows with repeating ON/OFF cycles. With support for up to three independent program groups, you can configure different operating periods throughout the day.


Why Choose the Time-R?

More than a basic plug-in timer, the TIME-R combines scheduled programming with flexible interval control in one compact unit. From everyday equipment scheduling to short, repeating operating cycles, it gives you greater control over compatible equipment in your hydroponic or growing setup.

TIME-R Digital Timer Instructions & Programming Guide

The TIME-R Digital Timer allows you to control electrical equipment using scheduled ON/OFF times or repeating intervals as short as one second. It supports three operating modes: Timed, Repeat and Combined.

Follow the instructions below to set the clock, program your timer and adjust its operation. For button layouts and diagrams, see the Official TIME-R instruction manual (PDF, opens in a new tab)

1. Before using your TIME-R timer

Before programming your timer:

  • Plug the timer into a wall socket and allow it to charge for at least two hours before first use.
  • Keep the timer indoors and in a dry location.
  • Check that the equipment connected to the timer does not exceed its rated electrical current.

2. Setting the clock

The timer's internal clock must be set to the correct time for scheduled programs to operate properly.

  • Press and hold the CLOCK button for approximately 3 seconds, until the time digits begin flashing.
  • Use the up and down arrow buttons to adjust the flashing digits.
  • Use the left and right arrow buttons to move between the time fields.
  • Press CONFIRM to save the current time.

The display should now show the correct time.

3. Switching between 12-hour and 24-hour time

The TIME-R can display time in either AM/PM format or 24-hour format.

  • Press and hold CONFIRM.
  • While holding CONFIRM, press the up arrow to change the time display format.
  • Select the desired format: 12-hour (AM/PM) or 24-hour.

4.  Timed Mode – Setting scheduled ON/OFF periods

Timed Mode allows you to program up to 15 ON/OFF settings per day. Use this mode when equipment needs to operate at specific times, such as switching a fan or light on and off according to a daily schedule.

To program Timed Mode:

  • Press MODE repeatedly until TIMED appears on the display.
  • Use the arrow buttons to select or adjust the first program group.
  • Set the desired ON time, using the up/down arrows to adjust the digits and the left/right arrows to move between fields.
  • Press CONFIRM to proceed to the OFF time.
  • Set the desired OFF time in the same way.
  • Press CONFIRM to save the group and move to the next group, if required.
  • Repeat the process for any additional ON/OFF periods.
  • After programming the required groups, press CONFIRM to complete the settings.

The timer will operate according to the programmed schedule. Check the display to confirm the next ON time, next OFF time and current time.

Example: To operate equipment from 6:30 am until 12:00 pm, set the ON time to 6:30 am and the OFF time to 12:00 pm.

5.  Repeat Mode – Setting an ON/OFF interval cycle

Repeat Mode switches equipment ON and OFF repeatedly using a programmed ON duration and OFF duration. Intervals can be set from one second up to 99 hours.

This mode is suitable for equipment that needs to run periodically rather than at fixed times of day.

To program Repeat Mode:

  • Press MODE repeatedly until REPEAT appears on the display.
  • Set the desired ON duration, using the arrow buttons to adjust the hours, minutes and seconds.
  • Press CONFIRM to proceed to the OFF duration.
  • Set the desired OFF duration.
  • Press CONFIRM to save the cycle.

The timer will repeatedly switch the connected equipment ON for the programmed ON duration, then OFF for the programmed OFF duration.

Example: To run equipment for 15 seconds and then leave it off for 59 minutes and 45 seconds, set the ON duration to 00:00:15 and the OFF duration to 00:59:45.

The cycle repeats continuously while the timer is operating in Repeat Mode.

6.  Combined Mode – Scheduling repeating ON/OFF cycles

Combined Mode combines the features of Timed Mode and Repeat Mode. It allows you to run a repeating ON/OFF cycle only within specified time windows. Up to three independent program groups can be configured.

Use this mode when equipment must cycle repeatedly during particular periods of the day, but remain inactive outside those periods.

To program Combined Mode:

  • Press MODE repeatedly until COMBINED appears on the display.
  • Select the first program group.
  • Set the group's start time and end time, as you would in Timed Mode.
  • Press CONFIRM to proceed to the Repeat Cycle settings.
  • Set the desired ON duration and OFF duration using the arrow buttons.
  • Press CONFIRM to save the group and proceed to another group if required.
  • Repeat the process for up to three groups.
  • Press CONFIRM to finish programming.

Within each programmed time window, the timer will repeatedly switch equipment ON and OFF according to the selected interval. Outside the programmed window, the cycle will not operate.

7. Manually switching the timer ON or OFF

You can override the timer's automatic operation using the buttons on the unit.

  • Manual OFF: Press the CLOCK button five times.
  • Manual ON: Press the CLEAR button five times.

Check the display to confirm the resulting ON or OFF status.

8. Locking and unlocking the settings

The TIME-R has a lock function to help prevent accidental changes to your programming.

  • To lock: After completing your settings, press CONFIRM three times.
  • To unlock: Press CONFIRM three times again.

When the timer is locked, an 'L' symbol appears on the display. The lock prevents changes through the MODE button, while the other buttons remain functional.

9. Checking your programmed settings

You can review your settings while the timer is operating.

  • Press CHECK once.
  • Press the right arrow to move through the pages showing each programmed setting.
  • Press CHECK again to return to normal operation.

To check the current time, press CLOCK once during normal operation.

10. Clearing or changing a program

If you need to remove or correct a program, use the CLEAR button while viewing or editing the relevant setting.

  • During programming: Press CLEAR once to clear the entire settings page. The display will show dashes.
  • To confirm deletion: Press CONFIRM to erase the setting.
  • To cancel the deletion: Press CLEAR again to return to the previous setting.

After making changes, check the display to ensure the correct settings have been saved.

11. Important safety information

  • Keep the timer indoors and in a dry location, whether in use or not.
  • Do not use the timer with power extension cords.
  • Ensure that connected equipment does not exceed the rated current.
  • Check the timer periodically and recharge it when necessary.
  • Do not open, dismantle or attempt to repair the timer yourself.

Rated current: Australia and New Zealand: 10 A (220–240 V, 50 Hz)

Need help programming your TIME-R timer? Contact Holland Forge if you need assistance with the timer's operating modes or settings.

Download the Official Instruction Manual (PDF)