Truncheon

The best selling hydroponics EC Meter in the world. Growers prefer the Bluelab Truncheon because it's easy to use, easy to read, extremely accurate and best of all it's reliable.

Use it to quickly and accurately test the conductivity levels (EC, CF & PPM) of your nutrient solution.


Features:

  • EC, CF and PPM scales
  • Fully waterproof
  • Factory calibrated
  • Auto turn on and off
  • Battery life minimum of one year (or shelf life of battery)
  • No external switches or adjustment knobs
  • EC (0.2 - 3.6), CF (2 - 36) and ppm scales (TDS and 700 scale)
  • Uses 3 x AA alkaline batteries (included)

Bluelab Truncheon

Testing is simple;

Dip the end of the Truncheon into the nutrient solution and wait for a minute or two for the Truncheon's probe to reach the same temperature as the nutrient.

  • Remove the Truncheon from the solution, and then dip back in again to take the reading.
  • The flashing lights along the side represent the value of the solution.
  • It doesn't get any easier.
  • Don't forget to rinse under fresh water after use, and clean once a week.

Handy Hint:  95% of all Truncheons returned to Holland Forge as 'Faulty' only require cleaning or new batteries. It's a great idea to buy a Cleaning Kit which contains everything you need, and check out the Cleaning Guide to keep your Truncheon in tip top condition.

Truncheon

Bluelab
9421024920012
Add to cart
Bluelab Truncheon

EC Probe Cleaning Kit

Bluelab
9421024920579
Add to cart
Bluelab Cleaning Kit

Probe cleaning is one of the most important parts of owning and operating any Bluelab meter. If the probe is contaminated or dirty, it affects the accuracy of the reading displayed.

The probe surface is where the instrument takes the reading of the solution. The information is sent back from the probe to the electronic brain of the instrument.

A calculation is then done in the instruments brain or micro computer and a reading is then displayed. If the information sent back from the probe is inaccurate due to probe surface contamination then the reading will be inaccurate.

Cleaning the probes is a very easy task and prolongs the life of the probes.


The Bluelab EC Cleaning Kit contains;

  • Instructions
  • 2 x 20ml single use Conductivity standard solution sachets
  • Plastic Cup
  • Probe cleaner
  • Cleaning Tool


The Bluelab EC Cleaning Kit contains;

  • Instructions
  • 2 x 20ml single use Conductivity standard solution sachets
  • Plastic Cup
  • Probe cleaner
  • Cleaning Tool



 Suits
 Bluelab EC Truncheon
 Bluelab Combo Meter
 Bluelab Guardian Monitor